Troubleshooting Your Chlorinator with Fluidra Pool App

Having trouble with your chlorinator? Let’s walk through some quick checks and solutions to get it working again.

🔌 Connectivity Issues

Is your chlorinator not responding or missing real-time data in the app?

✅ Try the following:

  • Make sure the chlorinator is installed in an area with strong Wi-Fi coverage.
  • The signal strength (RSSI) should be -60 dBm or better for reliable operation.
  • If the app seems stuck or not updating, disconnect the equipment from power for at least 2 minutes, then reconnect. This forces the device to refresh and send updated data to the cloud.

⚙️ Installation & Configuration

Did you install the chlorinator yourself and now see errors or missing parameters?

📘 Double-check the equipment manual to confirm proper setup.
🛠️ If issues persist, contact your authorized dealer or technician for support.

📉 Missing Parameters (pH, ORP, etc.)

Are values visible on the device but not in the app?

🔍 Your model may require an additional module to display those values.
📘 Check the manual for compatibility.
📩 If the app should show them and doesn’t, use the “Report an Issue” option in the app.
⚠️ If values are missing on both the device and app, it could be a sensor or hardware issue — contact your technician.

🌡️ Salinity Reading Shows “0”

Seeing a zero salinity value in the app?

💡 Salinity only appears when chlorine production is above 40%.
If production is below that, showing “0” is expected.

🚫 Chlorinator Only Produces in Boost Mode

Does chlorine production stop when Boost is turned off?

This may be due to a setting or alarm blocking normal production. Try these steps:

  1. 📺 On the device screen, check that Production % is not set to 0.
  2. ⚙️ Go to Configuration → Chlorine Control:
    • Ensure External Control (CLE) is OFF (unless using an external controller).
    • Keep Internal Control (CLI) OFF if not using an ORP sensor.
  3. 🔔 Check Information → Alarms for active messages like:
    • STOP Cl
    • Flow
    • Salt/Temperature

These alarms will stop chlorine production. Once resolved, normal operation should resume outside of Boost mode.

 

  